Norden Facade NF-CW50
50 mm curtain-wall series: 8 mullions and 6 transoms with section data and drawings.
Important: Values are nominal, calculated from geometry; to be confirmed by testing. Simplified sections, no thermal break shown.
Profile data
50 mm face width. Ix = moment of inertia about the axis parallel to the façade (wind-load bending); Wx = section modulus.
| Profile code | Type | Depth (mm) | Ix (cm⁴) | Wx (cm³) | kg/m | Alloy |
|---|---|---|---|---|---|---|
| NF-CW50-M65 | Mullion | 65 | 44.05 | 10.57 | 1.555 | EN AW-6063-T6 |
| NF-CW50-M85 | Mullion | 85 | 78.89 | 15.01 | 1.771 | EN AW-6063-T6 |
| NF-CW50-M105 | Mullion | 105 | 126.77 | 20.04 | 1.987 | EN AW-6063-T6 |
| NF-CW50-M125 | Mullion | 125 | 222.19 | 30.89 | 2.651 | EN AW-6063-T6 |
| NF-CW50-M150 | Mullion | 150 | 343.56 | 40.93 | 3.293 | EN AW-6063-T6 |
| NF-CW50-M175 | Mullion | 175 | 498.58 | 51.49 | 3.630 | EN AW-6063-T6 |
| NF-CW50-M200 | Mullion | 200 | 797.52 | 73.70 | 4.666 | EN AW-6005A-T6 |
| NF-CW50-M250 | Mullion | 250 | 1401.10 | 104.85 | 5.476 | EN AW-6005A-T6 |
| NF-CW50-T65 | Transom | 65 | 44.05 | 10.57 | 1.555 | EN AW-6063-T6 |
| NF-CW50-T85 | Transom | 85 | 78.89 | 15.01 | 1.771 | EN AW-6063-T6 |
| NF-CW50-T105 | Transom | 105 | 126.77 | 20.04 | 1.987 | EN AW-6063-T6 |
| NF-CW50-T125 | Transom | 125 | 209.24 | 28.82 | 2.473 | EN AW-6063-T6 |
| NF-CW50-T150 | Transom | 150 | 323.10 | 38.19 | 3.065 | EN AW-6063-T6 |
| NF-CW50-T175 | Transom | 175 | 468.17 | 48.00 | 3.376 | EN AW-6063-T6 |
Compatible transom pairings
Same face width; transom depth not greater than mullion depth. Recommended transom ≈ mullion depth − 15 mm.
| Mullion | Depth (mm) | Compatible transoms | Recommended |
|---|---|---|---|
| NF-CW50-M65 | 65 | NF-CW50-T65 | NF-CW50-T65 |
| NF-CW50-M85 | 85 | NF-CW50-T65, NF-CW50-T85 | NF-CW50-T65 |
| NF-CW50-M105 | 105 | NF-CW50-T65, NF-CW50-T85, NF-CW50-T105 | NF-CW50-T85 |
| NF-CW50-M125 | 125 | NF-CW50-T65, NF-CW50-T85, NF-CW50-T105, NF-CW50-T125 | NF-CW50-T105 |
| NF-CW50-M150 | 150 | NF-CW50-T65, NF-CW50-T85, NF-CW50-T105, NF-CW50-T125, NF-CW50-T150 | NF-CW50-T125 |
| NF-CW50-M175 | 175 | NF-CW50-T65, NF-CW50-T85, NF-CW50-T105, NF-CW50-T125, NF-CW50-T150, NF-CW50-T175 | NF-CW50-T150 |
| NF-CW50-M200 | 200 | NF-CW50-T65, NF-CW50-T85, NF-CW50-T105, NF-CW50-T125, NF-CW50-T150, NF-CW50-T175 | NF-CW50-T175 |
| NF-CW50-M250 | 250 | NF-CW50-T65, NF-CW50-T85, NF-CW50-T105, NF-CW50-T125, NF-CW50-T150, NF-CW50-T175 | NF-CW50-T175 |