Norden Facade NF-CW60
60 mm curtain-wall series: 8 mullions and 6 transoms with section data and drawings.
Important: Values are nominal, calculated from geometry; to be confirmed by testing. Simplified sections, no thermal break shown.
Profile data
60 mm face width. Ix = moment of inertia about the axis parallel to the façade (wind-load bending); Wx = section modulus.
| Profile code | Type | Depth (mm) | Ix (cm⁴) | Wx (cm³) | kg/m | Alloy |
|---|---|---|---|---|---|---|
| NF-CW60-M80 | Mullion | 80 | 75.48 | 15.31 | 1.825 | EN AW-6063-T6 |
| NF-CW60-M100 | Mullion | 100 | 123.52 | 20.57 | 2.041 | EN AW-6063-T6 |
| NF-CW60-M125 | Mullion | 125 | 241.37 | 33.78 | 2.786 | EN AW-6063-T6 |
| NF-CW60-M150 | Mullion | 150 | 371.33 | 44.51 | 3.495 | EN AW-6063-T6 |
| NF-CW60-M175 | Mullion | 175 | 536.40 | 55.68 | 3.833 | EN AW-6063-T6 |
| NF-CW60-M200 | Mullion | 200 | 856.32 | 79.43 | 4.909 | EN AW-6005A-T6 |
| NF-CW60-M225 | Mullion | 225 | 1146.58 | 95.11 | 5.314 | EN AW-6005A-T6 |
| NF-CW60-M250 | Mullion | 250 | 1493.26 | 112.06 | 5.719 | EN AW-6005A-T6 |
| NF-CW60-T80 | Transom | 80 | 75.48 | 15.31 | 1.825 | EN AW-6063-T6 |
| NF-CW60-T100 | Transom | 100 | 123.52 | 20.57 | 2.041 | EN AW-6063-T6 |
| NF-CW60-T125 | Transom | 125 | 227.00 | 31.48 | 2.597 | EN AW-6063-T6 |
| NF-CW60-T150 | Transom | 150 | 348.79 | 41.50 | 3.252 | EN AW-6063-T6 |
| NF-CW60-T175 | Transom | 175 | 503.13 | 51.86 | 3.562 | EN AW-6063-T6 |
| NF-CW60-T200 | Transom | 200 | 810.76 | 74.86 | 4.614 | EN AW-6063-T6 |
Compatible transom pairings
Same face width; transom depth not greater than mullion depth. Recommended transom ≈ mullion depth − 15 mm.
| Mullion | Depth (mm) | Compatible transoms | Recommended |
|---|---|---|---|
| NF-CW60-M80 | 80 | NF-CW60-T80 | NF-CW60-T80 |
| NF-CW60-M100 | 100 | NF-CW60-T80, NF-CW60-T100 | NF-CW60-T80 |
| NF-CW60-M125 | 125 | NF-CW60-T80, NF-CW60-T100, NF-CW60-T125 | NF-CW60-T100 |
| NF-CW60-M150 | 150 | NF-CW60-T80, NF-CW60-T100, NF-CW60-T125, NF-CW60-T150 | NF-CW60-T125 |
| NF-CW60-M175 | 175 | NF-CW60-T80, NF-CW60-T100, NF-CW60-T125, NF-CW60-T150, NF-CW60-T175 | NF-CW60-T150 |
| NF-CW60-M200 | 200 | NF-CW60-T80, NF-CW60-T100, NF-CW60-T125, NF-CW60-T150, NF-CW60-T175, NF-CW60-T200 | NF-CW60-T175 |
| NF-CW60-M225 | 225 | NF-CW60-T80, NF-CW60-T100, NF-CW60-T125, NF-CW60-T150, NF-CW60-T175, NF-CW60-T200 | NF-CW60-T200 |
| NF-CW60-M250 | 250 | NF-CW60-T80, NF-CW60-T100, NF-CW60-T125, NF-CW60-T150, NF-CW60-T175, NF-CW60-T200 | NF-CW60-T200 |
Section drawings
Important: Values are nominal, calculated from geometry; to be confirmed by testing. Simplified sections, no thermal break shown.
Have a drawing? Get a quote in 48 hours.
Upload DWG, DXF, STEP or PDF files. Our engineering team reviews feasibility, die cost and lead time.